I-Bedside SpO2 Patient Monitoring System yezingane ezisanda kuzalwa
Izimfanelo Zomkhiqizo
UHLOBO | I-Bedside SpO2 Patient Monitoring System \ NICU\ICU |
Isigaba | I-Bedside SpO2 Patient Monitoring System yezingane ezisanda kuzalwa |
Uchungechunge | narigmed®I-BTO-100CXX |
Iphakheji | 1pcs/ibhokisi, 8box/ibhokisi |
Uhlobo lokubonisa | 5.0 intshi LCD |
Bonisa ipharamitha | SPO2\PR\PI\RR |
Ibanga lokulinganisa le-SpO2 | 35%~100% |
Ukunemba kokulinganisa kwe-SpO2 | ±2% (70%~100%) |
Ibanga lokulinganisa le-PR | 30 ~ 250bpm |
Ukunemba kokulinganisa kwe-PR | Okukhulu okungu-±2bpm kanye ±2% |
Ukusebenza kwe-Anti-motion | I-SpO2±3% I-PR ±4bpm |
Ukusebenza kwe-perfusion ephansi | I-SPO2 ±2%, PR ±2bpm |
Isikhathi sokuqala sokuphuma/Isikhathi sokulinganisa | 4s |
ukugcotshwa okuphansi kungasekelwa okungenani | 0.025% |
Ukusebenza kwe-perfusion ephansi | I-SPO2 ±2%, PR ±2bpm |
I-perfusion Index Range | 0.02%~20% |
Izinga lokuphefumula | 4rpm ~ 70rpm |
Uhlelo lokuphatha i-alamu | YEBO |
Ukutholwa kokwehla kophenyo | YEBO |
idatha yethrendi yomlando | YEBO |
Ukuchofoza okukodwa ukuze uvale i-alamu | YEBO |
Ukuphathwa kohlobo lwesiguli | YEBO |
Abantu Abafanelekile | Ifanele ingane esanda kuzalwa engaphezu kuka-1Kg NOMA umuntu omdala |
Ukusetshenziswa kwamandla okujwayelekile | <40mA |
Izisindo | 803g (nesikhwama) |
I-Dimension | 26.5cm*16.8cm*9.1cm |
Isimo somkhiqizo | Imikhiqizo yokuzithuthukisa |
I-Voltage - Ukunikezwa | Uhlobo C 5V noma amandla ebhethri e-Lithium |
Izinga Lokushisa Lokusebenza | 5°C ~ 40°C 15%~95%( umswakamo) 50kPa~107.4kPa |
imvelo yokugcina | -20°C ~ 55°C 15%~95%( umswakamo) 50kPa~107.4kPa
|
Izici Ezilandelayo
1. Imisebenzi ebanzi: Ingakwazi ukukala izinkomba ezibalulekile zomzimba ezifana nokugcwala komoyampilo egazini (Spo2), izinga lokushaya kwenhliziyo (PR), izinga lokuphefumula (RR) kanye nemingcele ye-perfusion index (PI) yezingane ezisanda kuzalwa.
2. Ibanga elibanzi lokushaya kwenhliziyo: lisekela ukukalwa kwebanga lokushaya kwenhliziyo elibanzi kakhulu futhi livumelana nezimo ezishintshayo zokuguquguquka okusheshayo kwesilinganiso senhliziyo ezinganeni ezisanda kuzalwa.
3. Ukusetshenziswa kwendawo yonke yezandla nezinyawo: Kungakhathaliseki ukuthi izandla noma izinyawo, kungalinganiswa ngokunembile, kuxazululwe inkinga yezingane ezisanda kuzalwa ezinokujikeleza okungekuhle kwe-peripheral kanye nezimpawu ezibuthakathaka.
4. I-probe ekhethekile kanye nokwenza kahle kwe-algorithm: Ngokusebenzisa i-probe eklanywe ngokukhethekile kanye ne-algorithm yesofthiwe ehambisanayo, ngisho nasezimeni zokungahambi kahle kwegazi kanye nokufaka umoya okwanele ezinganeni ezisanda kuzalwa, amasignali angabanjwa futhi acutshungulwe ngempumelelo ukuze kuqinisekiswe ukuthi izinto ezihlukahlukene zingaboniswa ngokucacile.Inani elilinganiselwe.
Kafushane, i-oximeter ye-Narigmed brand neonatal oximeter inganikeza ukuqapha okunembile nokuthembekile kwemingcele ye-physiological ye-neonatal kuzilungiselelo zomtholampilo, ikakhulukazi ezimweni zezingane ezisanda kuzalwa ezinokujikeleza kwegazi okungazinzile noma ukugcwala okuphansi.