isibhengezo_sekhasi

Imikhiqizo

NOMK-01 SPO2 Ipharamitha Module

Incazelo emfushane:

I-algorithm yesofthiwe yobunikazi be-Narigmed ithuthukiswe ngokucophelela futhi yahlanganiswa nama-probe okuphathelene nezinhlelo zokuqapha ukuze kuhlangatshezwane nezidingo zokulinganisa zezilwane ezinosayizi abahlukahlukene.Kungakhathaliseki ukuthi ilinganisa izingxenye zokufafaza ezibuthakathaka, isistimu ingase futhi inikeze ukuhlaziywa kwedatha okunembe kakhulu futhi ingakhiqiza amanani ngokushesha nangokunembile.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Izimfanelo Zomkhiqizo

Igama Lomkhiqizo NOMK-01 Spo2 Ipharamitha Module
Usayizi 90mm*50mm*3mm
Izindlela zokufaka izintambo Uhlobo lwesokhethi/elinokuhlukaniswa
Isicelo Ingasetshenziswa kumnyango we-Neonatology
Ibanga lokulinganisa le-Spo2 35% ~ 100% ububanzi obubanzi kakhulu
Ukunemba kwesilinganiso se-Spo2 ±2%(70%~100%)
Ukunemba kwesilinganiso se-PR Okukhulu okungu-±2bpm no+2%
Ibanga lokubonisa le-PI 0.02%-20%
Ukusebenza kwe-Anti-motion(1~4Hz,1~2cm okulungisiwe/ukuphazamiseka kwefrikhwensi okungahleliwe) I-Spo2:+3%PR: enkulu engu-+4bpm kanye+4%
Ukusebenza kwe-perfusion ephansi I-Spo2 ±2%, PR ±2bpm
Isekela ukulinganisa okuphansi kwe-perfusion Ingaba ngaphansi njengo-0.025% nge-probe ye-Narigmed
Ukukhishwa kwe-Waveform Umdwebo webha/igagasi le-Pulse
Imodi yokuxhumana Umdwebo webha/igagasi le-Pulse
Hlola ukutholwa/ukuthola ukwehluleka kwe-Probe YEBO
Ukuphathwa kwe-alamu YEBO
Ukunikezwa kwamandla kagesi Uhlobo-C, 5V DC/<45mA
Isilinganiso sokuphefumula(RR) 4-70 rpm
Ibanga lokulinganisa le-PR 25~250bpm ububanzi obubanzi kakhulu

Incazelo emfushane

Ibhodi le-Narigmed® NOMK-01 SPO2\Imojuli yomoya-mpilo wegazi\SPO2.

I-oximeter ye-Narigmed ifanele ukukalwa kwemvelo okuhlukahlukene, njengendawo yokuphakama okuphezulu, ngaphandle, izibhedlela, amakhaya, ezemidlalo, nenkathi yasebusika, njll.

Ubuchwepheshe be-oksijini begazi be-Narigmed bungasetshenziswa ezikhathini ezahlukahlukene, abantu noma izilwane, futhi busetshenziswa odokotela ukukala umoya-mpilo wegazi, izinga lokushaya kwenhliziyo, izinga lokuphefumula kanye nenkomba yokugcwala.Ilungiselelwe futhi yathuthukiswa kakhulu ukuze kuvinjwe ukunyakaza nokusebenza okuphansi kwe-perfusion.Isibonelo, ngaphansi kokunyakaza okungahleliwe noma okuvamile ku-0-4Hz, 0-3cm, ukunemba kwe-pulse oximetry (SpO2) yi-± 3%, futhi ukunemba kokulinganisa kwezinga le-pulse yi-± 4bpm.Uma inkomba ye-perfusion ephansi inkulu noma ilingana no-0.025%, ukunemba kwe-pulse oximetry (SpO2) ingu-±2%, futhi ukunemba kokulinganisa kwezinga lokushaya kwenhliziyo ngu-±2bpm.